The FLIR CM85-2 is an industrial power clamp meter with advanced power analysis and variable frequency drive (VFD) filtering capabilities needed by electrical troubleshooters for large-scale equipment. Analyze voltage in complex machinery, including harmonics, inrush, current, and phase rotation tests, with a wide AC/DC voltage range and ±1% accuracy. Stream real-time data from the CM85-2 to your mobile device over Bluetooth®. The METERLiNK® program allows you to compare log files, set alert levels, visualize trends, and generate reports to share with team members.
Jaw Opening | 45 mm (1.77 in) |
---|---|
AC Current | 99.99 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits) 999.9 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits) |
Safety Category | CAT IV-600 V, CAT III-1000 V |
AC Current | 99.99 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits) 999.9 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits) |
AC Voltage | 99.99 V, 50–500 Hz ±(1.0% + 5 digits) 999.9 V, 50–500 Hz ±(1.0% + 5 digits) |
Capacitance | 3.999 μF, ±(1.9% + 8 digits) 39.99 μF, ±(1.9% + 8 digits) 399.9 μF, ±(1.9% + 8 digits) 3.999 mF, ±(1.9% + 8 digits) |
Continuity | 999.9 Ω, ±(1.0% + 5 digits) |
DC Current | 99.99 A, ±(2% + 0.5 A) 999.9 A, ±(2% + 5 digits) |
DC Voltage | 99.99 V, ±(0.7% + 2 digits) 999.9 V, ±(0.7% + 2 digits) |
Diode | 0.40 to 0.80 V, ±0.1 V |
Frequency | 20.00 to 99.99 Hz, ±(0.5% + 3 digits) 20.0 to 999.9 Hz, ±(0.5% + 3 digits) 0.020 to 9.999 kHz, ±(0.5% + 3 digits) |
Harmonics | Total harmonic distortion ACA/ACV: 99.9%, ±(3.0% + 10 digits) Harmonic distortion: H01–H12 99.9%, ±(5% + 10 digits) Harmonic distortion: H13–H25 99.9%, ±(10% + 10 digits) |
Inrush Current | ACA: 99.99 A, ±(3% + 0.3 A) 999.9 A, ±(3% + 5 digits) |
Measuring Rate | 3 times per second |
Peak Hold | ACV: 140.0 V, ±(3.0% + 15 digits) 1400 V, ±(3.0% + 15 digits) ACA: 140.0 A, ±(3.5% + 15 digits) 1400 A, ±(3.5% + 15 digits) |
Power Factor | -1.00 to 0.00 to +1.00, ±3° ±1 digit |
Recording | Data recording available via METERLiNK App |
Resistance | 999.9 Ω, ±(1.0% + 5 digits) 9.999 kΩ, ±(1.0% + 3 digits) 99.99 kΩ, ±(1.0% + 3 digits) |
VFD | ACV: 99.99 V, 50–60 Hz ±(1% + 5 digits) 999.9 V, 50–60 Hz ±(1% + 5 digits) ACA: 99.99 A, 50–60 Hz ±(2% + 5 digits) 999.9 A, 50–60 Hz ±(2% + 5 digits) |
Watts | DC: 9.999 kW (10 V, 5 A min), ±(3% + 0.05 kW) 99.99 kW (10 V, 5 A min), ±(3% + 0.5 kW) 999.9 kW (10 V, 5 A min), ±(3% + 10 digits) AC: 9.999 kW (10 V, 5 A min), ±(3% + 10 digits) 99.99 kW (10 V, 5 A min), ±(3% + 10 digits) 999.9 kW (10 V, 5 A min), ±(3% + 10 digits) |
Bluetooth range max | 10 m (32 ft) |
Auto Power Off | Approximately 30 minutes |
Battery life | 50 hours with alkaline batteries (backlight, work light, and Bluetooth are off) |
Power Requirements | 6 × 1.5 V AAA alkaline batteries |
Dimensions (L x W x H) | 276 mm × 101 mm × 50 mm (10.87 in × 3.98 in × 1.97 in) |
Jaw Opening | 45 mm (1.77 in) |
Weight | Total weight including batteries: 0.65 kg (1.43 lb) |
Worklights | Yes |
Certifications | UL, CE, FCC, IC, UKCA, CSAUS |
Drop test | 1.2 m (4 ft) |
EMC | FCC: 47 CFR Part 15 Subpart B CE: EN IEC 61326-1:2021 EN IEC 61326-2-2:2021 EN 301 489-1 V2.2.3 (2019-11) EN 301 489-17 V3.2.4 (2020-09) RF: ETSI EN 300 328 V2.2.2 EN 62479:2010 EN 50663:2017 |
Operating Temp & Humidity | 0°C to 10°C (32°F to 50°F) (non‐condensing) 10°C to 30°C (50°F to 86°F) (≤80% RH) 30°C to 40°C (86°F to 104°F) (≤75% RH) 40 to 50°C (104°F to 122°F) (≤45% RH) |
Safety Category | CAT IV-600 V, CAT III-1000 V |
Safety Standards | IEC 61010-1:2010, IEC 61010-2-032:2012, IEC 61010-2-033:2012 |
Shock & Vibration | Random vibration per MIL‐PRF‐28800F Class 2 (5 Hz to 55 Hz, 3 g maximum) |
Storage temperature and relative humidity [RH] | -10°C to 50°C (14°F to 122°F). 0–80% RH (batteries not fitted) |
Temperature Coefficient | 0.2 × (specified accuracy)/°C, <18°C, >28°C |
Warranty | Limited Lifetime Warranty www.flir.com/testwarranty |