FLIR CM85-2 True RMS Power Clamp Meter (Wireless)
True RMS Power Clamp Meter (Wireless)

The FLIR CM85-2 is an industrial power clamp meter with advanced power analysis and variable frequency drive (VFD) filtering capabilities needed by electrical troubleshooters for large-scale equipment. Analyze voltage in complex machinery, including harmonics, inrush, current, and phase rotation tests, with a wide AC/DC voltage range and ±1% accuracy. Stream real-time data from the CM85-2 to your mobile device over Bluetooth®. The METERLiNK® program allows you to compare log files, set alert levels, visualize trends, and generate reports to share with team members.

Specifications

Jaw Opening 45 mm (1.77 in)
AC Current 99.99 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
999.9 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
Safety Category CAT IV-600 V, CAT III-1000 V
AC Current 99.99 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
999.9 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
AC Voltage 99.99 V, 50–500 Hz ±(1.0% + 5 digits)
999.9 V, 50–500 Hz ±(1.0% + 5 digits)
Capacitance 3.999 μF, ±(1.9% + 8 digits)
39.99 μF, ±(1.9% + 8 digits)
399.9 μF, ±(1.9% + 8 digits)
3.999 mF, ±(1.9% + 8 digits)
Continuity 999.9 Ω, ±(1.0% + 5 digits)
DC Current 99.99 A, ±(2% + 0.5 A)
999.9 A, ±(2% + 5 digits)
DC Voltage 99.99 V, ±(0.7% + 2 digits)
999.9 V, ±(0.7% + 2 digits)
Diode 0.40 to 0.80 V, ±0.1 V
Frequency 20.00 to 99.99 Hz, ±(0.5% + 3 digits)
20.0 to 999.9 Hz, ±(0.5% + 3 digits)
0.020 to 9.999 kHz, ±(0.5% + 3 digits)
Harmonics Total harmonic distortion ACA/ACV: 99.9%, ±(3.0% + 10 digits)
Harmonic distortion: H01–H12 99.9%, ±(5% + 10 digits)
Harmonic distortion: H13–H25 99.9%, ±(10% + 10 digits)
Inrush Current ACA:
99.99 A, ±(3% + 0.3 A)
999.9 A, ±(3% + 5 digits)
Measuring Rate 3 times per second
Peak Hold ACV:
140.0 V, ±(3.0% + 15 digits)
1400 V, ±(3.0% + 15 digits)

ACA:
140.0 A, ±(3.5% + 15 digits)
1400 A, ±(3.5% + 15 digits)
Power Factor -1.00 to 0.00 to +1.00, ±3° ±1 digit
Recording Data recording available via METERLiNK App
Resistance 999.9 Ω, ±(1.0% + 5 digits)
9.999 kΩ, ±(1.0% + 3 digits)
99.99 kΩ, ±(1.0% + 3 digits)
VFD ACV:
99.99 V, 50–60 Hz ±(1% + 5 digits)
999.9 V, 50–60 Hz ±(1% + 5 digits)

ACA:
99.99 A, 50–60 Hz ±(2% + 5 digits)
999.9 A, 50–60 Hz ±(2% + 5 digits)
Watts DC:
9.999 kW (10 V, 5 A min), ±(3% + 0.05 kW)
99.99 kW (10 V, 5 A min), ±(3% + 0.5 kW)
999.9 kW (10 V, 5 A min), ±(3% + 10 digits)

AC:
9.999 kW (10 V, 5 A min), ±(3% + 10 digits)
99.99 kW (10 V, 5 A min), ±(3% + 10 digits)
999.9 kW (10 V, 5 A min), ±(3% + 10 digits)
Bluetooth range max 10 m (32 ft)
Auto Power Off Approximately 30 minutes
Battery life 50 hours with alkaline batteries (backlight, work light, and Bluetooth are off)
Power Requirements 6 × 1.5 V AAA alkaline batteries
Dimensions (L x W x H) 276 mm × 101 mm × 50 mm (10.87 in × 3.98 in × 1.97 in)
Jaw Opening 45 mm (1.77 in)
Weight Total weight including batteries: 0.65 kg (1.43 lb)
Worklights Yes
Certifications UL, CE, FCC, IC, UKCA, CSAUS
Drop test 1.2 m (4 ft)
EMC FCC:
47 CFR Part 15 Subpart B

CE:
EN IEC 61326-1:2021
EN IEC 61326-2-2:2021
EN 301 489-1 V2.2.3 (2019-11)
EN 301 489-17 V3.2.4 (2020-09)

RF:
ETSI EN 300 328 V2.2.2
EN 62479:2010
EN 50663:2017
Operating Temp & Humidity 0°C to 10°C (32°F to 50°F) (non‐condensing)
10°C to 30°C (50°F to 86°F) (≤80% RH)
30°C to 40°C (86°F to 104°F) (≤75% RH)
40 to 50°C (104°F to 122°F) (≤45% RH)
Safety Category CAT IV-600 V, CAT III-1000 V
Safety Standards IEC 61010-1:2010, IEC 61010-2-032:2012, IEC 61010-2-033:2012
Shock & Vibration Random vibration per MIL‐PRF‐28800F Class 2 (5 Hz to 55 Hz, 3 g maximum)
Storage temperature and relative humidity [RH] -10°C to 50°C (14°F to 122°F). 0–80% RH (batteries not fitted)
Temperature Coefficient 0.2 × (specified accuracy)/°C, <18°C, >28°C
Warranty Limited Lifetime Warranty
www.flir.com/testwarranty
Contact Us
Feel free to contact us if you have any questions