The Extech AN300-C is an airflow cone and funnel adapter kit. For use with the AN300, AN310, and AN320 meters. The accessory kit enables rapid and easy airflow measurements in common large-size ducts.
The SDL350 saves data to an SD card in Excel format. Air Velocity/Flow meter with telescopic probe that fits into HVAC ducts and other narrow apertures. The telescoping probe has a maximum length of 7.05ft (215cm) with cable. The data sample rate is adjustable. Stores 99 manual readings and 20M readings on a 2GB SD card. Type K/J thermocouple input for high-temperature measurements. The large (9999 count) LCD displays both air velocity or flow and temperature at the same time. Record and recall MIN, MAX, Data Hold, and Auto Power Off. Comes with 6 AA batteries, an SD card, a telescopic probe with cable, and a protective carrying bag.
Air Velocity (ft/min) | 40 to 3940ft/min |
---|---|
Air Velocity (ft/min) Basic Accuracy | ±5% of reading |
Air Velocity (ft/min) Max Resolution | 1ft/min |
Air Velocity (km/h) | 0.7 to 72km/h |
Air Velocity (km/h) Basic Accuracy | ±5% of reading |
Air Velocity (km/h) Max Resolution | 0.01km/h |
Air Velocity (knots) | 1 to 31knots |
Air Velocity (knots) Basic Accuracy | ±5% of reading |
Air Velocity (knots) Max Resolution | 0.01knots |
Air Velocity (m/s) | 0.2 to 25m/s |
Air Velocity (m/s) Basic Accuracy | ±5% of reading |
Air Velocity (m/s) Max Resolution | 0.01m/s |
Air Velocity (mph) | 0.5 to 45MPH |
Air Velocity (mph) Basic Accuracy | ±5% of reading |
Air Velocity (mph) Max Resolution | 0.01MPH |
Air Volume (CFM) | 0 to 1,907,000 CFM |
Air Volume (CFM) Max Resolution | 0.001 to 1 CMM |
Air Volume (CMM) | 0 to 54,000 CMM |
Memory | 20 Million data records using 2G SD card |
Temperature (Air) | 32 to 122 °F (0 to 50 °C) |
Temperature (Air) Basic Accuracy | ±1.5°F ( ±0.8°C) |
Temperature (Air) Max Resolution | 0.1° |
Temperature (Type J) Basic Accuracy | -148 to 2192 °F (-100 to 1200 °C) |
Temperature (Type J) Max Resolution | ±(0.4% + 1.8 °F/1 °C) |
Temperature (Type K) Basic Accuracy | 0.1° |
Temperature (Type K) Max Resolution | -148 to 2372 °F (-100 to 1300 °C) |
Temperature (Type N) | 0.1° |
Temperature (Type N) Basic Accuracy | ±(0.4% + 1.8 °F/1 °C) |
Certifications | CE |
Dimensions | 7.2 × 2.9 × 1.9" (182 × 73 × 47.5mm) |
Power | 6 × AA (1.5V) batteries |
Warranty | 3 years |
Weight | 23.1oz (655g) |
The SDL310 saves data to an SD card in Excel format. Air temperature is measured to 122°F (50°C), and air velocity is 4930 feet per minute. Stores 99 manual readings and 20M readings on a 2GB SD card. Stores 99 manual readings and 20M readings on a 2GB SD card. Type K/J thermocouple input for high-temperature measurements. The large (9999 count) LCD displays both air velocity and temperature. On a 39-inch vane wheel, low friction ball bearings provide 2% velocity accuracy. (1 m) cable. Record/recall the minimum, maximum, data hold, and auto power off. The data sample rate is adjustable. Comes contains 6 AA batteries, an SD card, a vane sensor with a 3.9ft (120cm) wire, and a protective carrying bag.
Air Velocity (ft/min) | 80 to 4930ft/min |
---|---|
Air Velocity (ft/min) Basic Accuracy | ±2% of reading |
Air Velocity (ft/min) Max Resolution | 1ft/min |
Air Velocity (km/h) | 1.4 to 90.0km/h |
Air Velocity (km/h) Basic Accuracy | ±2% of reading |
Air Velocity (km/h) Max Resolution | 0.1km/h |
Air Velocity (knots) | 0.8 to 48.6knots |
Air Velocity (knots) Basic Accuracy | ±2% of reading |
Air Velocity (knots) Max Resolution | 0.1knots |
Air Velocity (m/s) | 0.4 to 25m/s |
Air Velocity (m/s) Basic Accuracy | ±2% of reading |
Air Velocity (m/s) Max Resolution | 0.01m/s |
Air Velocity (mph) | 0.9 to 55.9MPH |
Air Velocity (mph) Basic Accuracy | ±2% of reading |
Air Velocity (mph) Max Resolution | 0.1MPH |
Memory | 20,000K data records using 2G SD card |
Temperature (Air) | 32 to 122 °F (0 to 50 °C) |
Temperature (Air) Basic Accuracy | ±1.5 °F (±0.8 °C) |
Temperature (Air) Max Resolution | 0.1° |
Temperature (Type J) Basic Accuracy | -148 to 2192 °F (-100 to 1200 °C) |
Temperature (Type J) Max Resolution | ±(0.4% of reading + 1.8°F/1°C) |
Temperature (Type K) Basic Accuracy | 0.1° |
Temperature (Type K) Max Resolution | -148 to 2372 °F (-100 to 1300 °C) |
Temperature (Type N) | ±(0.4% + 1.8°F/1°C) |
Temperature (Type N) Basic Accuracy | 0.1° |
Certifications | CE |
Dimensions | 7.2 × 2.9 × 1.9" (182 × 73 × 47.5mm) |
Power | 6 × AA (1.5V) batteries |
Warranty | 3 years |
Weight | 16.9oz (480g) |
The SDL300 saves data to an SD card in Excel format. The metal vane can endure temperatures up to 158°F (70°C) and air velocity up to 6900ft/min. Dataloggers date and time stamp readings and store them on an SD card in Excel format for easy transfer to a PC. The data sample rate can be set anywhere between 1 and 3600 seconds. Stores 99 manual readings and 20M readings on a 2GB SD card. Type K/J thermocouple input for high-temperature measurements. The large (9999 count) LCD displays both air velocity and temperature. 2% velocity accuracy with low friction ball bearing vane wheel on 39" (1m) wire. Record/Recall MIN, MAX, Data Hold, Auto Power Off. Complete with 6 x AA batteries, SD card, metal vane sensor with 3.9ft (120cm) cable, and sturdy carrying bag.
Air Velocity (ft/min) | 60 to 6900ft/min |
---|---|
Air Velocity (ft/min) Basic Accuracy | ±2% of reading |
Air Velocity (ft/min) Max Resolution | 1ft/min |
Air Velocity (km/h) | 1.0 to 126.0km/h |
Air Velocity (km/h) Basic Accuracy | ±2% of reading |
Air Velocity (km/h) Max Resolution | 0.1km/h |
Air Velocity (knots) | 0.6 to 68knots |
Air Velocity (knots) Basic Accuracy | ±2% of reading |
Air Velocity (knots) Max Resolution | 0.1knots |
Air Velocity (m/s) | 0.4 to 35m/s |
Air Velocity (m/s) Basic Accuracy | ±2% of reading |
Air Velocity (m/s) Max Resolution | 0.1m/s |
Air Velocity (mph) | 0.7 to 78.2MPH |
Air Velocity (mph) Basic Accuracy | ±2% of reading |
Air Velocity (mph) Max Resolution | 0.1MPH |
Memory | 20M data records using 2G SD card |
Temperature (Air) | 32 to 158 °F (0 to 70 °C) |
Temperature (Air) Basic Accuracy | ±1.5°F/0.8°C (<60°C) |
Temperature (Air) Max Resolution | 0.1 ° |
Temperature (Type J) Basic Accuracy | -148 to 2192 °F (-100 to 1200 °C) |
Temperature (Type J) Max Resolution | ±(0.4% + 1.8°F/1°C) |
Temperature (Type K) Basic Accuracy | 0.1° |
Temperature (Type K) Max Resolution | -148 to 2372 °F (-100 to 1300 °C) |
Temperature (Type N) | ±(0.4% of reading + 1.8°F/1°C) |
Temperature (Type N) Basic Accuracy | 0.1° |
Certifications | CE |
Dimensions | 7.2 × 2.9 × 1.9" (182 × 73 × 47.5mm) |
Power | 6 × AA (1.5V) batteries |
Warranty | 3 years |
Weight | 17.2oz (487g) |